SIU-C VOLTAGE & FREQUENCY PROTECTION RELAY

SIL-G FEEDER & GENERATOR PROTECTION RELAY

The SIU-C represents the best and most precise protection solution for transformers and electrical machines, in high, medium, and low-voltage distribution systems. The SIU-C is a voltage and frequency protection relay and also protects decoupling, load shedding, and loss of main (islanding),  universal with an auxiliary power supply of 24-230 Vdc/ac.

Notable for the capability of measuring up to 1.000 volts when it is connected directly to the low-voltage line. Voltage measurement: 5 voltage channels for conventional.

To allow the communication, relays are provided with a local micro USB front port and with remote communication with different options ports and protocols; Rear RS485 Port: IEC60870-5-103, Modbus RTU, or DNP3.0 Serial. RJ45 Port: Modbus TCP/IP, DNP3.0 TCP/IP or IEC60870-5-104 + Web Server + SNTP Protocol.

The SIU-C is provided with 11 configurable inputs and 5 configurable outputs. It is provided with non-volatile RAM memory in order to store up to 3072 events and disturbance fault recording (DFR), maintaining date & time thanks to its internal RTC (real Time Clock).

Fanox counts, with its own SICom Communications Program, allows the oscillography record to be downloaded and saved in COMTRADE format (IEEE C37.111-1991)

    • The SIU-C is a voltage and frequency protection relay for transformers and electrical machines, in high, medium, and low voltage distribution systems. Also protects decoupling, load shedding, and loss of main (islanding), universal with auxiliary the power supply of 24-230 Vdc/ac.
    • Voltage measurement: 5 voltage channels for conventional VTs.
    • The capability of measuring up to 1.000 volts when it is connected directly to the low voltage line.
    • Metallic box with high electromagnetic compatibility level (EMC) and a wide range of operating temperatures.
    • Protection of decoupling, load shedding, and loss of main (islanding). Loss of Main (islanding) occurs when part of the public utility network loses connection with the rest of the system. If this situation is not detected, then the generator could remain connected, causing a safety hazard within the network. Automatic reconnection of the generator to the network may occur causing damage to the generator and the network. SIU-C protection relay detects this situation thanks to its voltage and frequency functions focused on the Rate of change of frequency (ROCOF) method.
     
    • Signaling/control of the circuit breaker (52 function) and the recloser (79 function).
    • To allow the communication, relays are provided with a local micro USB front port and with remote communication with different options (ports and protocols) on the rear side:
      • Rear RS485 Port: IEC60870-5-103, Modbus RTU or DNP3.0 Serial.
      • Rear RJ45 Port: Modbus TCP/IP, DNP3.0 TCP/IP or IEC60870-5-104 + Web Server + SNTP Protocol
    • Synchronization through IRIG-B is optional depending on the model.
    • The SIU-C is provided with 11 configurable inputs and 5 configurable outputs.
    • The SIU-C is fitted with the demand of voltage (Load Data Profiling) with the following characteristics:
      • The number of records: 2160.
      • Recording mode circular.
      • Sampling rate (interval): configurable through communications (1-60 min).
    • An alarms panel is available.
    • SIU-C is provided with non-volatile RAM memory in order to store up to 3072 events and disturbance fault recording (DFR), maintaining date & time thanks to its internal RTC (Real Time Clock).
      • 5 records in data and COMTRADE format (300 cycles each record): 1 to 8 pre-fault cycles + 292 to 299 postfault cycles.
      • 25 records in data and COMTRADE format (60 cycles each record): 1 to 8 pre-fault cycles + 52 to 59 postfault cycles.
      • 50 records in data and COMTRADE format (30 cycles each record): 1 to 8 pre-fault cycles + 22 to 29 postfault cycles.
      • 100 records in data and COMTRADE format (15 cycles each record): 1 to 8 pre-fault cycles + 7 to 14 postfault cycles.)
    • The oscillography is downloaded by a communications port.
      The SICom communications program allows the oscillography record to be downloaded and saved in COMTRADE format (IEEE C37.111-1991).

59 Phase overvoltage (Bus Bar)
59-L Phase overvoltage (Line)
59N/G Calculated/Measured neutral overvoltage (Bus Bar)
47 Phase Balance voltage protection (Bus Bar)
27 Phase Undervoltage (Bus Bar)
27-L Phase undervoltage (Line)
27V1 Positive sequence Undervoltage (Bus Bar)
∆V/∆t Rate of change of voltage
81O/U Under/Overfrequency
81R Rate of change of Frequency (ROCOF)
78 Out of Step (Vector Shift)
24 Overfluxing
79 AC Reclosing device
HLT Hot Line Tag
52 Breaker wear monitoring
25 Synchro Check
BF Circuit Breaker Failure
74TCS Trip Circuit Supervision
74CCS Close Circuit Supervision
49T External Trip
86 Trip lockout
PGC Programmable logic control

ADDITIONAL FUNCTIONS

CNT Counters
RTC Real Time Clock
ALRM Alarm panel
PGC Programmable Logic Control
HMI Human Machine Interface
SER Sequential Event Recording
DFR Disturbance Fault Recording
LDP Load Data Profiling
MET Metering
STTG Settings Groups
CMMD Commands

Communication Software for SIA & SIL protection relays

The SICom PC software has been designed and programmed to gain access to all of Fanox relays information, to modify the settings and configuration, check states and measurements and to analyse and save events and fault reports using a graphic-friendly user interface.

SICom software works with the Windows®7, Windows®8, Windows®8.1 y Windows®10 operating system.

  • General data reading: Complete model, Version, Serial number, etc.
  • States reading
  • Measurements reading
  • Reading and changing settings
  • Reading and changing configuration
  • Reading and deleting events
  • Reading and deleting fault reports
  • Reading and deleting demand current (load data profiling)
  • Reading and saving oscillographic records in Comtrade format
  • Changing the user passwords
  • Saving and Loading settings files
  • Saving and Loading configuration files
  • Saving events and fault reports
  • Saving demand current (load data profiling)
  • Date-time synchronization
  • Configuring the communication parameters
  • Reading and changing counters
  • Commands for opening and closing the circuit breaker and block/unblock the recloser
  • Configuration of the inputs
  • Configuration of the outputs
  • Configuration of the causes that start a Fault Report

The update of the software does not require any user´s action, this is, if the computer is connected to Internet, SICom updates itself when it is started.
It will allow you to prepare all the settings and relay configurations without having the relay connected to the PC (offline mode), reducing engineering and commissioning time.
SICom program uses Modbus protocol, so only the ports with this protocol can be used to establish the communication.

 SIL-ASIU-CSIL GSIL-C
TypeOC & EF PROTECTIONVOLTAGE & FREQUENCY PROTECTIONLINE, FEEDER AND GENERATOR PROTECTIONLINE, FEEDER AND GENERATOR PROTECTION
Auxiliary Supply24-230 Vdc/Vac24-230 Vdc/Vac24-48Vdc or 48-230 Vac/dc or 24-230 Vac/dc24-230 Vdc/Vac
Consumption3,3 – 4,5 W< 6 W. 24-230 Vdc/Vac < 10VA24-48 Vdc and 48-230 Vac/dc < 10VA. 24-230Vac/dc < 20VA24-230Vac/dc < 20VA
Current measurementStandard CT > 0,5VAn/aStandard CT > 0,5VAStandard CT > 0,5VA
LPCTn/an/an/an/a
Voltage measurementn/aVT or directly to the low voltage lineVT or directly to the low voltage lineVT or directly to the low voltage line
VT connection typen/aAdjustableAdjustableAdjustable
502n/a22
50G2n/a11
50N2n/a11
50/512n/a4 levels of 67 *4 levels of 67 *
50/51G2n/a2 levels of 67G *2 levels of 67G *
50/51N2n/a2 levels of 67N *2 levels of 67N *
67GI1n/a11
67NI1n/a11
50/51/67G1n/a**
50/51/67n/an/a**
SOFT1n/a11
64REF1n/a11
521111
BF1111
491n/a11
49T1111
791111
HLTn/a
461n/a11
CLP1n/a11
74TCS1111
74CCSn/a1n/an/a
Trip Block1n/a11
68 (Trip Bus)1111
8611
46BCn/a11
60CTS1n/a11
60VTSn/an/a11
Programmable LogicV3V3
371n/a11
59n/a222
59N1322
47n/a111
27n/a422
27V1n/a211
32/40n/an/a44
81U/On/a844
25n/a111
24n/a222
59-Ln/a111
27-Ln/a111
81Rn/a644
78n/a211
IRIG-Bn/aOptionalOptionalOptional
Counters
Commands
Sett. Group4444
Inputs3 / 5 / 6 / 9118 / 16 / 24 / 8 + 4 AFD11
Outputs3 / 4 / 5 / 6 / 757 / 11 / 18 / 7 + 4 HS-O5
LEDs8 configurable11 configurable11 configurable11 configurable
HMI20x2 LCD + 11 keys20x4 LCD + 13 key20x4 LCD + 13 keys20x4 LCD + 13 keys
52 & 79 HMI2 LEDs + 4 keys2 LEDs + 4 keys2 LEDs + 4 keys3 LEDs + 4 keys
Event2048307230723072
Fault Reportconfigurable up to 100configurable up to 100configurable up to 100configurable up to 100
OscillographyConfigurable up to 100 recordsconfigurable up to 100configurable up to 100configurable up to 100
Current demandn/a
Local Port (frontal)Micro USBMicro USBMicro USBMicro USB
Remote Port (rear)RS485 or EthernetRS485 or EthernetRS485 or Ethernet or Fiber OpticRS485 or Ethernet
Communications ProtocolsRS485 (ModBus RTU or IEC60870-5-103 or DNP3.0 Serial) RJ45 (Modbus TCP/IP or DNP3 TCP/IP or IEC 60870-5-104) RJ45 (IEC61850) + SNTP protocolRS485(ModBus RTU or DNP3.0 Serial or IEC60870-5-103) RJ45 (Modbus TCP/IP or DNP3.0 TCP/IP or IEC60870-5-104) + SNTP protocolRS485(ModBus RTU or DNP3.0 Serial or IEC60870-5-103) RJ45(Modbus TCP/IP or DNP3.0 TCP/IP or IEC60870-5-104) RJ45(IEC 61850) FO-LC(IEC61850) + SNTP protocolRS485(ModBus RTU or DNP3.0 Serial or IEC60870-5-103) RJ45 (Modbus TCP/IP or DNP3.0 TCP/IP or IEC60870-5-104) + SNTP protocol
Size of177 x 107 mm177 x 107 mm198 x 187 mm177 x 107 mm

 